Radiography Components - Technical Specifications
|
X-ray tubes
- Dual-focus rotating anode tubes: Focal spots: 0.3mm/1.0mm; 0.6mm/1.0mm; 0.6mm/1.2mm
- Excellent lifetime
- Tube overload protection
|
Back to top
|
Generators: Optimus 50/65/80
- Wide range of applications
- Available configurations: 50 kW, 65 kW, 80 kW
- Features
- Anatomically Programmed Radiography (APR)
- Tube Overload Protection
- Automatic Exposure Control
- Tomography Density Control
- Variofocus
- Area dose calculator
- Documentation of post-exposure data
|
Back to top
|
Ceiling suspension CS
- Ceiling suspended tube carrier with four-part telescopic column
- Smooth-running unit can be moved longitudinally and transversely
- Award-winning Bucky control grip allows easy and one-hand operation, and positioning close to the patient
- Handling is quick and easy
- Longitudinal travel: 3,530 mm (11’7”)
6,030 mm (19’ 5.8”) with rail extensions
- Transverse travel:
- 1,474 mm with BuckyDiagnost CS2
- 3,194 mm with BuckyDiagnost CS4
- Vertical travel: 1,480 mm (4’ 10.3”)
|
Back to top
|
Floor stand standard FS-S
- Floor Stand for full scalability
- Horizontal tube support arm facilitates high flexibility in changing transverse positioning
- Glides on flat profile rails
- Large travel range along the table enables use from all sides
- Rotation of tube carrier arm : +/- 90°
- Rotation of tube head around horizontal axis: +/- 125 °
- Vertical movement of tube carrier arm: 1,600 mm (5’33”)
- Min. room height: 2,420 mm (7’11.3”)
- Min. / Max. source-room distance: 400 / 2,000 mm (15.8”/6’6.7)
|
Back to top
|
Floor stand compact FS-C
- For compact system set-up, not necessarily against a wall
- L-shaped tube arm carrier ensures a generous SID, also for lateral exposures
- Available with one floor- and one wall- or ceiling-rail
- Large travel range permits X-ray exposure from head to toe
- Rotation of tube carrier arm : +/- 90°
- Rotation of tube head around horizontal axis: +/- 125°
- Vertical movement of tube carrier arm: 1,590 mm (5’2.6”)
- Min. room height: 2,400 mm (7’10.5”)
- Min. /Max. source-floor distance: 310 / 1,900 mm (12.2”/6’2.8”)
|
Back to top
|
Floor stand fix FS-F
- Fixed to the floor
- Optimized for modern, high-performance chest rooms
- X-ray tube assembly is mounted directly on to the column for chest room solutions
- Additional horizontal tube arm available to enable exposures using a patient trolley
- Automatic collimation as standard, tracking optional
- Rotation of tube carrier arm (option) : +/- 90°
- Rotation of tube head around horizontal axis: +/- 125°
- Vertical movement of tube carrier arm: 1,600 mm (5’3”)
- Min. room height: 2,400 mm (7’10.5”)
- Min. / Max. source-floor distance: 300 / 1,900 mm (11.8”/6’2.8”)
|
Back to top
|
Bucky table TH2, conventional and digital
- Height-adjustable patient table with a large range of movements
- Easy handling ensures a quick patient positioning
- Easy patient transferring in recumbent or seated positions
- Floating tabletop of sandwich design with Getalit overlay
- With DigitalDiagnost flat detector it becomes a digital Bucky table
- Dimensions (l x w)
- 2,400 mm x 750 mm (7’10.5” x 29.5”)
- 2,400 mm x 850 mm (7’10.5” x 33.5”) (optional)
- Height adjustment: 515 mm (20.3”) to 915 mm (36”) above the floor; motorized adjustment
- Max. patient weight:
- 210 kg (460 lbs) dynamic load off center
- 318 kg (700 lbs) dynamic load center
- 375 kg (820 lbs) static load center
|
Back to top
|
Fixed Bucky table TF
- Designed for all standard radiography applications
- Easy handling enables quick and convenient work
- Wide floating tabletop with Kevlar overlay
- Available with Automatic Cassette Load (ACL4)
- Dimensions (l x w):
- 2,400 mm x 750 mm (7’10.5” x 29.5”)
- 2,000 mm x 750 mm (7’10.5” x 33.5”) (optional)
- Max. patient weight: 210kg (460 lbs)
|
Back to top
|
Traumob X
- Mobile table designed for conventional radiography applications
- Freely revolving castors with brakes
- Tiltable table top 10°
- Dimensions (l x w): 1955mm x 550mm (6’5” x 21.7”)
- Height of tabletop above floor: 715mm–1065mm (28.2” x 3’5.9”)
- Max. patient weight: 135 kg (297 lbs)
- Table weight: 67 kg
|
Back to top
|
Single side suspended table TH-S
- Single side suspended height-adjustable table
- Ideally suited for use with DigitalDiagnost VM – the multi-purpose stand with swiveling tube arm
- Floating tabletop allows for quick and easy patient positioning
- Regulation via foot pedal for working close to the patient
- Dimensions (l x w): 2,600 mm x 750 mm (8’ 6.4” x 29.5”)
- Length of X-ray transparent area: 2080 mm (6’ 9.9”)
- Height adjustment: 503 mm to 903 mm above floor (19.8” to 35.6”); motorized adjustment
- Max. patient weight: 225 kg (496 lbs)
|
Back to top
|
Height adjustable trolley TA-M
- Floating tabletop of sandwich design with carbon fiber overlay
- Easy and safe handling with 2 foot pedals on each side
- All accessories for the table TH-S can be used with this trolley as well
- Dimension of standard version:
- 2,200 mm x 620 mm (7’2.6” x 24.4”)
- X-ray transparent area of standard version: 1,730mm x 620mm (5’8.1” x 24.4”)
- Height of tabletop above floor: 870mm (34.3”)
- Max. patient weight: 225 kg (496 lbs)
- Weight of trolley: 130 kg (286 lbs)
|
Back to top
|
Vertical stand VE
- Compact vertical stand with large range of vertical movements for the Bucky unit
- Easy handling
- Motor-controlled oscillating grid
- 3 automatic exposure control chambers
- Dimensions
- Height: 2,240 mm
- Vertical movement of Bucky unit: 380 mm to 1,900 mm (central beam)
- Optional tracking for synchronized vertical movement with Bucky CS2/4
|
Back to top
|
Vertical stand VT with ACL 4
- Equipped with tiltable Bucky unit (tilting range: - 20° / + 90°)
- Can be used as small table for all kinds of extremities and special skull projection
- Motor-controlled oscillating grid
- 3 automatic exposure control chambers
- Dimensions
- Height: 2,240 mm
- Vertical movement of Bucky unit: 380 mm to 1,900 mm (central beam)
- Angle of tilt Bucky unit: -20° to +90°
- Optional tracking for synchronized vertical movement with Bucky CS2/4
|
Back to top
|
Vertical stand VS
- Equipped with tiltable Bucky unit (tilting range: - 20° / + 90°)
- Can be used as small table for all kinds of extremities and special skull projection
- Motor-controlled oscillating grid
- 3 automatic exposure control chambers
- Dimensions
- 596mm x 575mm (23.5“ x 22.6“)
- Vertical movement range: 1500mm (4’)
- Optional tracking for synchronized vertical movement with Bucky CS2/4
- Weight: 130 kg-255 kg, depending on version
|
Back to top
|
Vertical stand VS with digital detector
- Motorized vertical stand with digital detector
- Adjustable by a left and right hand control unit and/or wireless remote control
- Tiltable detector (option), angle of tilt –20° to +90°, motorized tilting
- Grid storage for up to two grids within the detector unit
- 5 automatic exposure control chambers
- Dimensions
- Height: 2,080 mm (6’ 9.9“)
- Vertical movement of detector unit: 300 mm to 1,800 mm (11.8” to 5.1”) (central beam)
|
Back to top
|
Fixed multi-purpose vertical stand VM compact
- Fixed vertical stand with a multi-purpose swivelling arm for full application flexibility with just one detector
- Detector positions for under table and wall stand work
- Angle of tilt horizontal axis: -20° to +90°, motorized
- Swivelling range multi-purpose arm: 0° to 90° (right or left operator side)
- Grid storage for up to two grids within the detector unit
- 3 automatic exposure control chambers
- Dimensions
- Height: 2,380 mm (7’9.7”)
- Vertical movement of detector unit: 350 mm to 1,850 mm (13.8” to 6.1”)(central beam)
|
Back to top
|
Moveable multi-purpose stand VM
- Moveable vertical stand with a multi-purpose swivelling arm for full application flexibility with just one detector
- Adjustable by a left and right hand control unit and/or wireless remote control
- Detector is tiltable and moveable e.g. underneath the single side suspended table
- Angle of tilt horizontal axis: -20° to +90°, motorized tilting
- Angle of tilt vertical axis: +45° to -23°, motorized tilting
- Swivelling range multi-purpose arm: 0° to 90° (right or left operator side)
- Grid storage for up to two grids within the detector unit
- 5 automatic exposure control chambers
- Dimensions
- Height: 2,480 mm (8’1.6”)
- Movement ranges:
- Horizontal movement range:
- motorized 3,475mm (11’4.8”)
- non-motorized 3.710mm (12’2.1”)
- Vertical movement range : 350 mm to 1,850 mm (13.8” to 6’ 1”) (central beam)
|
Back to top
|
Bucky unit family
- Digital or conventional use (detectors or cassettes)
- Usable x-ray field 43 cm by 43 cm
- Automatic exposure control
- Oscillating grid
|
Back to top
| Philips Computed Radiography (PCR) |
|
|
We offer a number of different CR Readers for different departmental set-ups with integrated single or multi-slot high-resolution readers.
Read more
|
Back to top
| Additional DigitalDiagnost specifications |
|
|
Detector
- Technology: Cesium iodide scintillator, amorphous silicon
- Active detector area: 43 cm by 43 cm
- Matrix size: 3000 by 3000 pixel
- Pixel size: 143 µm by 143 µm
- Pixel data: 14 bit
|
Back to top
|
Operator console
- High performance SUN Workstation
- Advanced image processing software
- UNIQUE image processing software (optional)
- Workflow software
- DICOM Software
- Various RIS / Printer / PACS connection possibilities
|
Back to top
|
Optional DICOM functionalities
- DICOM WLM – Work List Management
- DICOM MPPS – Modality Performed Procedure Step
- DICOM Grayscale Standard Display Functions / Export Filter
- DICOM Print
- DICOM Print Editor
- DICOM Media (CD-R)
|
Back to top |
|