Note: the images on this page are representative of the Achieva XR at it's inital 1.5T field strength, before upgrade. View Achieva XR clinical images after upgrade to 3.0T
|   |
 |  | 3D TOF 0.3 x 0.3 x 0.7 mm 100 slices, scan time 5:34 min Click image to run movie (815 kb) | T2W TSE using SENSE Head coil 0.4 x 0.4 x 5.0 mm 22 slices, scan time 2:27 min |
|
|   |
|
|   |
 | Total Spine imaging Left: T2W TSE, 0.5 x 0.5 x 5.0 mm, 9 slices, 2:20 min Right: STIR TSE, 0.4 x 0.4 x 5 mm, 9 slices, scan time 2:15 min |
|
|   |
|
Back to top
|   |
 |  | Fast B-TFE 0.4 x 0.4 x 1.5 mm 32 slices, scan time 1:32 min | T1W-FFE 0.5 x 0.5 x 3.0 mm 15 slices, scan time 3:30 min |
|
|   |
|
|   |
 | Total Neuro Imaging using SENSE Head Spine coil 4 stations, FOV 1080 mm |
|
|   |
|
Back to top
|   |
 |  | Single Shot T2W TSE with SENSE XL Torso coil Breath hold 21 seconds FOV 475 x 500 mm 25 slices, 1.1 x 1.1 x 7.0 mm | Large FOV fat suppression with IR-TSE Breath hold 21 seconds FOV 475 x 500 mm 25 slices, 1.3 x 1.3 x 7.0 mm |
|
|   |
|
|   |
 |  | Single-slice short axis view with SENSE 30 phases in 21 sec breath hold 0.8 x 0.8 x 8.0 mm Click image to run movie (448 kb) | Single-slice Black Blood imaging, Short axis view Left: Proton Density weighted, 0.7 x 0.7 x 8.0 mm, breath hold 17 sec Right: T2 weighted, 0.7 x 0.7 x 8.0 mm, breath hold 17 sec |
|
|   |
|
|   |
 |  | Excellent fat suppression with PDW TSE SPAIR 1.0 x 1.4 x 3.0 mm, 20 slices scan time 4:41 min | Excellent contrast resolution with m-FFE 1.0 x 1.2 x 3.0 mm, 16 slices, scan time 5:19 min |
|
|   |
|
|   |
 | Total Body Imaging with the integrated body coil T2W TSE, FOV 530 x 2000 mm 1.0 x 1.0 x 6.0 mm |
|
|   |
|
Back to top
|   |
 |  | T2W TSE with SENSE using SENSE Body coil 0.6 x 0.6 x 3.0 mm, 40 slices Scan time 2:06 | DWIBS with SENSE using the SENSE XL Torso coil 1.5 x 1.5 x 7.0 mm Click image to run movie (362 kb) |
|
|   |
|
|   |
 |  | Non-contrast Angio using b-TFE with fat suppression Portal Circulation, 0.8 x 0.8 x 7.0 mm 25 slices, scan time 2:19 min Click image to run movie (1,972 kb) | Non-contrast Angio using b-TFE with fat suppression Renal arteries, 0.6 x 0.6 x 1.5 mm 30 slices, breath hold 18 sec |
|
|   |
|
|   |
 | Large FOV 500mm T1W TSE SENSE 0.5 x 0.5 x 3.0 mm, scan time 4:18 min |
|
|   |
|
Back to top
|   |
 |  | Off center fat suppression with SENSE Flex M coil T2W TSE SPAIR 0.3 x 0.3 x 3.5 mm, scan time 2:56 min | Off center imaging with SENSE Flex M coil PDW TSE with a-TSE 0.3 x 0.3 x 3.5 mm, scan time 3:00 min |
|
|   |
|
|   |
 |  | Excellent contrast resolution with m-FFE SENSE Wrist coil 0.1 x 0.1 x 2.0 mm, 18 slices scan time 4:34 min | Excellent resolution with PDW TSE with a-TSE SENSE Wrist coil 0.1 x 0.1 x 2.5 mm, 14 slices, scan time 3:45 min |
|
|   |
|
Note: the images on this page are representative of the Achieva XR at it's inital 1.5T field strength, before upgrade. View Achieva XR clinical images after upgrade to 3.0T